{"product_id":"otdr-launch-cable-box-2000m-dead-zone-eliminator-sc-fc-lc-st","title":"2000m OTDR Launch Cable Box – Dead Zone Eliminator, G652D Fiber, SC FC LC ST UPC APC","description":"\u003ch2\u003e2000m OTDR Launch Cable Box – Dead Zone Eliminator for Accurate Near-End Fiber Testing | G652D | SC \/ FC \/ LC \/ ST | UPC \u0026amp; APC\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e2000m OTDR Launch Cable Box\u003c\/strong\u003e is a field-ready fiber optic launch cable assembly containing \u003cstrong\u003e2,000 meters of G652D singlemode fiber\u003c\/strong\u003e wound inside a ruggedized, IP-rated hard-shell case. It connects between the OTDR and the fiber link under test to \u003cstrong\u003eeliminate the OTDR’s near-end dead zone\u003c\/strong\u003e, enabling accurate measurement of insertion loss and reflectance at the first connector of the link — measurements that would otherwise be masked by the OTDR’s launch pulse recovery time.\u003c\/p\u003e\n\n\u003cp\u003eAvailable with \u003cstrong\u003eSC, FC, LC, and ST\u003c\/strong\u003e connectors in both \u003cstrong\u003eUPC and APC\u003c\/strong\u003e polish, the 2000m launch cable box is the standard tool for OTDR testing of long-haul singlemode fiber links, FTTH feeder cables, and telecom OSP fiber where the near-end connector loss and reflectance must be accurately characterized.\u003c\/p\u003e\n\n\u003ch2\u003eWhat Is an OTDR Launch Cable Box and Why Is 2000m Needed?\u003c\/h2\u003e\n\u003cp\u003eEvery OTDR has a \u003cstrong\u003edead zone\u003c\/strong\u003e at the beginning of a trace — a blind region caused by the recovery time of the OTDR’s receiver after the high-power launch pulse. During this dead zone, the OTDR cannot accurately measure events (connectors, splices, faults) on the fiber. The dead zone has two components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Dead Zone (EDZ):\u003c\/strong\u003e The minimum distance after a reflective event (such as a connector) before the OTDR can detect another event — typically 1–5 meters for modern OTDRs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttenuation Dead Zone (ADZ):\u003c\/strong\u003e The minimum distance after a reflective event before the OTDR can accurately measure loss — typically 10–80 meters depending on OTDR model and pulse width setting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy inserting a \u003cstrong\u003e2000m launch cable\u003c\/strong\u003e between the OTDR and the link under test, the OTDR’s dead zone is pushed 2,000 meters into the launch cable — well before the first connector of the actual link. This allows the OTDR to accurately measure:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003einsertion loss and reflectance of the near-end connector\u003c\/strong\u003e of the link under test\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eloss of the first splice\u003c\/strong\u003e in the link\u003c\/li\u003e\n\u003cli\u003eAny \u003cstrong\u003efaults or events near the launch end\u003c\/strong\u003e of the fiber that would otherwise be hidden in the dead zone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA \u003cstrong\u003e2000m launch cable\u003c\/strong\u003e is recommended for OTDRs with longer pulse widths (used for long-haul testing) where the attenuation dead zone can extend to several hundred meters, and for applications where the first connector or splice of the link must be accurately characterized.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2,000m G652D Singlemode Fiber:\u003c\/strong\u003e ITU-T G652.D compliant singlemode fiber — the standard fiber type for FTTH, telecom OSP, and long-haul applications. Low attenuation (\u0026lt;0.5dB total at 1310nm for 2000m) ensures the launch cable itself does not significantly reduce OTDR dynamic range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRuggedized Hard-Shell Case:\u003c\/strong\u003e SR Polypropylene case with compound latch and locking feature — protects the fiber from damage in field environments. Water and dust resistant for indoor and outdoor use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Carabiner Clip:\u003c\/strong\u003e Allows the launch box to be clipped to a belt, ladder, or equipment rack during testing — keeping both hands free\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Cable Management:\u003c\/strong\u003e Fiber is neatly wound inside the case with built-in cable management — no tangling or kinking during deployment and retrieval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-Purge Valve:\u003c\/strong\u003e Prevents pressure buildup inside the sealed case during temperature changes — maintains case integrity in outdoor environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSC \/ FC \/ LC \/ ST Connectors, UPC \u0026amp; APC:\u003c\/strong\u003e Available in the most common singlemode connector types and polish types — select the configuration that matches your OTDR port and the fiber link under test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Meter Lead Cables:\u003c\/strong\u003e 3mm buffer lead cables on both ends provide strain relief and easy connection to the OTDR port and the fiber link under test\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFiber \u0026amp; Connector Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eG652D (ITU-T G652.D singlemode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Length\u003c\/td\u003e\n\u003ctd\u003e2,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Length\u003c\/td\u003e\n\u003ctd\u003e2 meters, 3mm buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Loss\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.5dB @ 1310nm (2000m total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Types\u003c\/td\u003e\n\u003ctd\u003eSC, FC, LC, ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolish Types\u003c\/td\u003e\n\u003ctd\u003eUPC, APC, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss (UPC)\u003c\/td\u003e\n\u003ctd\u003e≥50dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss (APC)\u003c\/td\u003e\n\u003ctd\u003e≥60dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss (PC)\u003c\/td\u003e\n\u003ctd\u003e≥35dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤0.2dB (1,000 mating cycles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExchangeability\u003c\/td\u003e\n\u003ctd\u003e≤0.2dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eMechanical \u0026amp; Environmental Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Dimensions\u003c\/td\u003e\n\u003ctd\u003e238mm × 141mm × 67mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eSR Polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Color\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (without fiber)\u003c\/td\u003e\n\u003ctd\u003e0.75kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCompliance Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eITU-T G652.D (singlemode fiber)\u003c\/li\u003e\n\u003cli\u003eITU-T G656.A\u003c\/li\u003e\n\u003cli\u003eITU-T G651.1 OM1, OM2, OM3, OM4\u003c\/li\u003e\n\u003cli\u003eIEC 60793-2-10 Type A1a.1\/A1b (OM1\/OM2), Type A1a.2 (OM3), Type A1a.3 (OM4)\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant — Directive 2011\/65\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use the OTDR Launch Cable Box\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the correct connector configuration\u003c\/strong\u003e — match the launch cable’s connector type (SC\/FC\/LC\/ST) and polish (UPC\/APC) to your OTDR’s optical port and the fiber link under test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the connectors\u003c\/strong\u003e — inspect and clean both the OTDR port and the launch cable connectors before connecting. Contaminated connectors are the most common cause of poor OTDR traces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the launch cable to the OTDR\u003c\/strong\u003e — plug one end of the launch cable into the OTDR’s optical port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the launch cable to the fiber under test\u003c\/strong\u003e — plug the other end of the launch cable into the first connector of the fiber link under test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the OTDR range and pulse width\u003c\/strong\u003e — set the OTDR range to cover the full length of the fiber link plus the 2000m launch cable. The OTDR trace will show the launch cable as the first 2000m of fiber before the link under test begins\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcquire the OTDR trace\u003c\/strong\u003e — the near-end connector of the link under test will now appear clearly in the OTDR trace, outside the dead zone, with accurate loss and reflectance measurements\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003e2000m vs. 500m vs. 1000m Launch Cable: Which Length Do You Need?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLaunch Cable Length\u003c\/th\u003e\n\u003cth\u003eRecommended Use Case\u003c\/th\u003e\n\u003cth\u003eDead Zone Coverage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e500m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-range testing, OTDRs with short pulse widths, FTTH drop fiber testing\u003c\/td\u003e\n\u003ctd\u003eCovers EDZ and ADZ for most modern OTDRs at short pulse widths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1000m\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium-range testing, standard FTTH feeder and distribution fiber testing\u003c\/td\u003e\n\u003ctd\u003eCovers ADZ for most OTDRs at medium pulse widths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2000m\u003c\/strong\u003e (this listing)\u003c\/td\u003e\n\u003ctd\u003eLong-haul testing, OTDRs with long pulse widths, applications requiring accurate near-end connector characterization\u003c\/td\u003e\n\u003ctd\u003eCovers ADZ for all OTDRs including those with long pulse widths (\u0026gt;1µs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eWe also stock 500m and 1000m OTDR launch cable boxes in the same connector configurations — see our related listings.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-haul singlemode fiber testing\u003c\/strong\u003e — OTDR characterization of trunk fiber, feeder cables, and backbone fiber where long pulse widths create extended dead zones requiring a 2000m launch cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFTTH feeder fiber testing\u003c\/strong\u003e — accurate measurement of near-end connector loss at the OLT or splitter input on FTTH feeder cables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTelecom OSP fiber acceptance testing\u003c\/strong\u003e — IEC\/ITU-compliant OTDR testing of newly installed outside plant fiber cables, including accurate near-end connector characterization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber fault location\u003c\/strong\u003e — locating breaks, high-loss splices, and connector faults near the launch end of a fiber link that would otherwise be hidden in the OTDR dead zone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBidirectional OTDR testing\u003c\/strong\u003e — used as both a launch cable (from one end) and a receive cable (from the other end) for bidirectional OTDR measurements required by IEC 61280-4-1 and TIA-568 fiber acceptance standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is an OTDR launch cable box?\u003c\/strong\u003e\u003cbr\u003e\nA: An OTDR launch cable box is a fiber optic cable assembly — typically 500m to 2000m of singlemode fiber wound in a protective case — that is connected between the OTDR and the fiber link under test. It pushes the OTDR’s dead zone away from the beginning of the link, allowing accurate measurement of the near-end connector and events close to the launch end of the fiber.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Why do I need a 2000m launch cable instead of 500m or 1000m?\u003c\/strong\u003e\u003cbr\u003e\nA: The required launch cable length depends on your OTDR’s attenuation dead zone (ADZ) at the pulse width you are using. For long-haul testing with long pulse widths (\u0026gt;1µs), the ADZ can extend to several hundred meters — a 2000m launch cable ensures the dead zone is fully contained within the launch cable for all OTDR models and pulse width settings. For short-range testing with short pulse widths, a 500m or 1000m launch cable is usually sufficient.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What connector type and polish should I choose?\u003c\/strong\u003e\u003cbr\u003e\nA: Choose the connector type (SC, FC, LC, or ST) that matches your OTDR’s optical port and the fiber link under test. Choose \u003cstrong\u003eAPC\u003c\/strong\u003e (green connector, 8° angled) if your OTDR port or fiber link uses APC connectors — common in FTTH and PON networks. Choose \u003cstrong\u003eUPC\u003c\/strong\u003e (blue connector) for standard telecom and enterprise fiber applications. APC and UPC connectors are not interchangeable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this launch cable box as a receive cable?\u003c\/strong\u003e\u003cbr\u003e\nA: Yes. The launch cable box can be used as both a launch cable (connected at the near end of the OTDR) and a receive cable (connected at the far end of the fiber link) for bidirectional OTDR testing. Bidirectional testing is required by IEC 61280-4-1 and TIA-568 for fiber acceptance testing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What fiber type is used in this launch cable box?\u003c\/strong\u003e\u003cbr\u003e\nA: The launch cable uses \u003cstrong\u003eITU-T G652.D singlemode fiber\u003c\/strong\u003e — the standard singlemode fiber type for FTTH, telecom OSP, and long-haul applications. It is compatible with all standard singlemode OTDRs operating at 1310nm and 1550nm.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the case waterproof?\u003c\/strong\u003e\u003cbr\u003e\nA: The case is water and dust resistant, rated for indoor and outdoor use across a wide temperature range (-40°C to +85°C). It features an auto-purge valve to prevent pressure buildup during temperature changes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: For support or bulk orders?\u003c\/strong\u003e\u003cbr\u003e\nA: Contact us at info@splicermarket.com for B2B pricing, volume orders, or technical support.\u003c\/p\u003e\n\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2000m OTDR Launch Cable Box (G652D fiber, selected connector type and polish) ×1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TEKCN","offers":[{"title":"APC\/SC \/ APC\/SC","offer_id":48998099943736,"sku":"Launch-cable-cable-2000M-1","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ APC\/FC","offer_id":48998099976504,"sku":"Launch-cable-cable-2000M-2","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ APC\/LC","offer_id":48998100009272,"sku":"Launch-cable-cable-2000M-3","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ APC\/ST","offer_id":48998100042040,"sku":"Launch-cable-cable-2000M-4","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ UPC\/SC","offer_id":48998100074808,"sku":"Launch-cable-cable-2000M-5","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ UPC\/FC","offer_id":48998100107576,"sku":"Launch-cable-cable-2000M-6","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ UPC\/LC","offer_id":48998100140344,"sku":"Launch-cable-cable-2000M-7","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/SC \/ UPC\/ST","offer_id":48998100173112,"sku":"Launch-cable-cable-2000M-8","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ APC\/SC","offer_id":48998100205880,"sku":"Launch-cable-cable-2000M-9","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ APC\/FC","offer_id":48998100238648,"sku":"Launch-cable-cable-2000M-10","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ APC\/LC","offer_id":48998100271416,"sku":"Launch-cable-cable-2000M-11","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ APC\/ST","offer_id":48998100304184,"sku":"Launch-cable-cable-2000M-12","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ UPC\/SC","offer_id":48998100336952,"sku":"Launch-cable-cable-2000M-13","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ UPC\/FC","offer_id":48998100369720,"sku":"Launch-cable-cable-2000M-14","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ UPC\/LC","offer_id":48998100402488,"sku":"Launch-cable-cable-2000M-15","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/FC \/ UPC\/ST","offer_id":48998100435256,"sku":"Launch-cable-cable-2000M-16","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ APC\/SC","offer_id":48998100468024,"sku":"Launch-cable-cable-2000M-17","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ APC\/FC","offer_id":48998100500792,"sku":"Launch-cable-cable-2000M-18","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ APC\/LC","offer_id":48998100533560,"sku":"Launch-cable-cable-2000M-19","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ APC\/ST","offer_id":48998100566328,"sku":"Launch-cable-cable-2000M-20","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ UPC\/SC","offer_id":48998100599096,"sku":"Launch-cable-cable-2000M-21","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ UPC\/FC","offer_id":48998100631864,"sku":"Launch-cable-cable-2000M-22","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ UPC\/LC","offer_id":48998100664632,"sku":"Launch-cable-cable-2000M-23","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/LC \/ UPC\/ST","offer_id":48998100697400,"sku":"Launch-cable-cable-2000M-24","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ APC\/SC","offer_id":48998100730168,"sku":"Launch-cable-cable-2000M-25","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ APC\/FC","offer_id":48998100762936,"sku":"Launch-cable-cable-2000M-26","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ APC\/LC","offer_id":48998100795704,"sku":"Launch-cable-cable-2000M-27","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ APC\/ST","offer_id":48998100828472,"sku":"Launch-cable-cable-2000M-28","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ UPC\/SC","offer_id":48998100861240,"sku":"Launch-cable-cable-2000M-29","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ UPC\/FC","offer_id":48998100894008,"sku":"Launch-cable-cable-2000M-30","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ UPC\/LC","offer_id":48998100926776,"sku":"Launch-cable-cable-2000M-31","price":169.0,"currency_code":"USD","in_stock":true},{"title":"APC\/ST \/ UPC\/ST","offer_id":48998100959544,"sku":"Launch-cable-cable-2000M-32","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ APC\/SC","offer_id":48998100992312,"sku":"Launch-cable-cable-2000M-33","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ APC\/FC","offer_id":48998101025080,"sku":"Launch-cable-cable-2000M-34","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ APC\/LC","offer_id":48998101057848,"sku":"Launch-cable-cable-2000M-35","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ APC\/ST","offer_id":48998101090616,"sku":"Launch-cable-cable-2000M-36","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ UPC\/SC","offer_id":48998101123384,"sku":"Launch-cable-cable-2000M-37","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ UPC\/FC","offer_id":48998101156152,"sku":"Launch-cable-cable-2000M-38","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ UPC\/LC","offer_id":48998101188920,"sku":"Launch-cable-cable-2000M-39","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/SC \/ UPC\/ST","offer_id":48998101221688,"sku":"Launch-cable-cable-2000M-40","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ APC\/SC","offer_id":48998101254456,"sku":"Launch-cable-cable-2000M-41","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ APC\/FC","offer_id":48998101287224,"sku":"Launch-cable-cable-2000M-42","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ APC\/LC","offer_id":48998101319992,"sku":"Launch-cable-cable-2000M-43","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ APC\/ST","offer_id":48998101352760,"sku":"Launch-cable-cable-2000M-44","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ UPC\/SC","offer_id":48998101385528,"sku":"Launch-cable-cable-2000M-45","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ UPC\/FC","offer_id":48998101418296,"sku":"Launch-cable-cable-2000M-46","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ UPC\/LC","offer_id":48998101451064,"sku":"Launch-cable-cable-2000M-47","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/FC \/ UPC\/ST","offer_id":48998101483832,"sku":"Launch-cable-cable-2000M-48","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ APC\/SC","offer_id":48998101516600,"sku":"Launch-cable-cable-2000M-49","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ APC\/FC","offer_id":48998101549368,"sku":"Launch-cable-cable-2000M-50","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ APC\/LC","offer_id":48998101582136,"sku":"Launch-cable-cable-2000M-51","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ APC\/ST","offer_id":48998101614904,"sku":"Launch-cable-cable-2000M-52","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ UPC\/SC","offer_id":48998101647672,"sku":"Launch-cable-cable-2000M-53","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ UPC\/FC","offer_id":48998101680440,"sku":"Launch-cable-cable-2000M-54","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ UPC\/LC","offer_id":48998101713208,"sku":"Launch-cable-cable-2000M-55","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/LC \/ UPC\/ST","offer_id":48998101745976,"sku":"Launch-cable-cable-2000M-56","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ APC\/SC","offer_id":48998101778744,"sku":"Launch-cable-cable-2000M-57","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ APC\/FC","offer_id":48998101811512,"sku":"Launch-cable-cable-2000M-58","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ APC\/LC","offer_id":48998101844280,"sku":"Launch-cable-cable-2000M-59","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ APC\/ST","offer_id":48998101877048,"sku":"Launch-cable-cable-2000M-60","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ UPC\/SC","offer_id":48998101909816,"sku":"Launch-cable-cable-2000M-61","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ UPC\/FC","offer_id":48998101942584,"sku":"Launch-cable-cable-2000M-62","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ UPC\/LC","offer_id":48998101975352,"sku":"Launch-cable-cable-2000M-63","price":169.0,"currency_code":"USD","in_stock":true},{"title":"UPC\/ST \/ UPC\/ST","offer_id":48998102008120,"sku":"Launch-cable-cable-2000M-64","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0058\/7923\/4648\/products\/1_354890f7-c513-46a3-bd14-21582ec1fe33.jpg?v=1601483206","url":"https:\/\/www.opticfibertool.com\/products\/otdr-launch-cable-box-2000m-dead-zone-eliminator-sc-fc-lc-st","provider":"Fusion Splicer Store","version":"1.0","type":"link"}